Boiler Water Treatment B90 (30Ltr /Jer)
Treat Boiler to have lower pressure (17.5 kg/cm2 – 250 psi). Cocok untuk boiler bertekanan rendah.
Boiler Water Treatment Chemical B90
PT SEDAYA MITRA SEJAHTERA adalah Distributor/Supplier di Indonesia (Jakarta) yang menjual (sell) Boiler Water Treatment Chemical B90, fuel absorbent sock, oil boom, super oil absorbent pads, sorbent pad, rig wash cleaning, granular absorbent, dll dengan harga kompetitif.
Boiler Water Treatment Chemical B90
Boiler Water Treatment Chemical B90 merupakan produk dengan formula yang dirancang khusus untuk memelihara air ketel bertekanan rendah (17,5 Kg/cm2 – 250 psi).
KEGUNAAN dari Boiler Water Treatment Chemical B90:
- Boiler Water Treatment Chemical Mencegah terjadinya korosi dan karat serta kerak air pada ketel
- Boiler Water Treatment Chemical Menghilangkan keasaman air
- Boiler Water Treatment Chemical Dapat menahan lumpur air sehingga mudah dicerat waktu pembuangan air
- Boiler Water Treatment Chemical Bereaksi kimiawi dengan kesadahan air dalam ketel dengan membentuk lumpur air
KEUNTUNGAN dari Boiler Water Treatment Chemical B90:
- Boiler Water Treatment Chemical Bersifat multi fungsi untuk memelihara air ketel, mudah pemakaian dan pengontrolannya dengan Test Kit yang sederhana
- Boiler Water Treatment Chemical Dapat mempertahankan kapasitas produksi steam
- Boiler Water Treatment Chemical Dapat memperpanjang umur tekhnis ketel, terutama pipa-pipanya
PEMAKAIAN
- Pada Boiler yang bertekanan rendah
- Pada economizer sampai tekanan 200 psi
CARA PEMAKAIAN
Tuangkan Boiler Water Treatment Chemical B90 kedalam tangki pengisian atau pada isapan pompa pengisian air ketel. Dosis pemakaian adalah 6 liter untuk setiap ton air dalam ketel. Cara pengaturan dosis dapat dilakukan dengan Test Kit Boiler Water Treatment Chemical B90.
PENGONTROLAN DOSIS
Pengontrolan dosis Boiler Water Treatment Chemical B90 dilakukan dengan test alkalinitas “P” dari air ketel kira-kira 100 sampai 300 ppm.
Jika pembacaan hasil test alkalinitas “P” kurang dari 100ppm perlu diberikan tambahan Boiler Water Treatment Chemical B90 untuk setiap ton air ketel akan menaikkan pembacaan testing alkalinitas “P” sebesar + 170ppm.
Setelah penambahan Boiler Water Treatment Chemical B90 tunggu 1 jam sebelum diadakan test ulang.
Bila test alkalinitas “P” melebihi standar 100 – 300ppm, karena dosis terlalu tinggi atau alkalinitas air pengisian memang tinggi, maka ketel perlu dicerat sampai nilai 100 – 300ppm “P” alkalinitas tercapai lagi. Baru kemudian ditambah dengan air yang lebih baik.
Boiler Water Treatment Chemical b90
Boiler Water Treatment Chemical B90 it is a design formula to treat Boiler to have lower pressure (17.5 kg/cm2 – 250 psi)
FUNCTION of Boiler Water Treatment Chemical B90:
-
Boiler Water Treatment Chemical To protect corrosion and rust and slag water onto boiler
-
Boiler Water Treatment Chemical To eliminate water acid
-
Boiler Water Treatment Chemical To resistance with clay and easy to process when deposal
-
Boiler Water Treatment Chemical reaction to water into Boiler to contruct clay water
ADVANTAGE of Boiler Water Treatment Chemical B90:
-
Multi function characteristic to treat Boiler water, easy to use and control and simple Test Kit
-
To maintaint steam production capacity
-
To expand Boiler economic period specific pipes
PROCEDURE
-
Low pressure Boiler
-
It is economizer with 200 psi
DIRECTION FOR USE
-
Please pour Boiler Water Treatment Chemical B90 to tank or suction pump of Boiler.
-
Your dosage 6 Liter per ton water Boiler. To control your dosage, use Test Kit AR – TB.90
HOW TO CONTROL YOUR DOSAGE
To control your dosage with alkaline test “P” from Boiler approximately 100 to 300 ppm. If your test shown less 10ppm, you shall be added our Boiler Water Treatment Chemical B90. Additional 6 Liter per ton water Boiler, shown alkaline test is approximately 170 ppm.
After finished, please you wait for one hour before re-test.
If your test allow more 100-300 ppm, as your high dosage as well as water alkaline to fill that also is high, your boiler pressured to 100-300 ppm allow, then added water is better
Salinity Control or Boiler Water Chloride Grade / Draw Off Boiler Water
Salty control or chloride grade to boiler to test with Test Kit of Chloride from Boiler Water Treatment Chemical AR – B 90.
The result of chloride test will directly be blowdown to water or not boiler. Chloride is not change if chemical reaction into boiler to mineral grade into boiler.
The result of chloride test shown at 200 ppm as normal chloride or salty.
If chloride test shown more 200 ppm that blow down and it should be filled with clean water.
CAUTION
Keep a dry, and keep away friom flammable point, if pour, wash with water immediately, keep away directly contact from your skin and eyes, if any wash with clean water immediately
Boiler Water Treatment Chemical b90
boiler water treatment chemical, armi b.90, specialty chemical, jual boiler water treatment chemical, jual armi b.90, jual specialty chemical, boiler water treatment chemical supplier, supplier armi b.90, specialty chemical supplier
Boiler Water Treatment Chemical B90
PT SEDAYA MITRA SEJAHTERA adalah Distributor/Supplier di Indonesia (Jakarta) yang menjual (sell) Boiler Water Treatment Chemical B90, fuel absorbent sock, oil boom, super oil absorbent pads, sorbent pad, rig wash cleaning, granular absorbent, dll dengan harga kompetitif.
Hubungi kami untuk konfirmasi stock Boiler Water Treatment Chemical B90.
>>> Click Here to Contact Us <<<
Untuk informasi lebih lengkap mengenai Boiler Water Treatment Chemical B90, penyerap tumpahan kimia, silahkan menghubungi kami (021) 5694-6288 atau WA: 0856-9822-188 / 0856-8068-188, email: info@ptsedaya.co.id